Performance and air supply
Provide loaded speed, running torque, minimum starting torque, dynamic inlet pressure and available flow.
Custom selection reference
Start with a target power class and drive configuration, then assess operating speed, torque and installation requirements.
| Reference | Configuration | Target power class | To be defined |
|---|---|---|---|
| 01 | Geared vane motor | 20 / 30 W | Loaded speed, running and starting torque, ratio and air supply |
| 02 | Geared vane motor | 80 / 100 W | Loaded speed, running and starting torque, ratio and air supply |
| 03 | Geared vane motor | 90 / 120 / 170 W | Loaded speed, running and starting torque, ratio and air supply |
| 04 | Geared vane motor | 100 / 200 / 280 W | Loaded speed, running and starting torque, ratio and air supply |
| 05 | Geared vane motor | 130 / 300 / 400 W | Loaded speed, running and starting torque, ratio and air supply |
| 06 | Geared vane motor | 300 / 600 / 850 W | Loaded speed, running and starting torque, ratio and air supply |
| 07 | Geared vane motor | 900 / 1100 W | Loaded speed, running and starting torque, ratio and air supply |
| 08 | Geared vane motor | 700 / 1600 / 2200 W | Loaded speed, running and starting torque, ratio and air supply |
| 09 | Low-speed, high-torque concept | 300 / 400 W | Low-speed stability, gearing capacity, shaft and axial/radial loads |
| 10 | Low-speed, high-torque concept | 600 / 850 W | Low-speed stability, gearing capacity, shaft and axial/radial loads |
| 11 | Low-speed, high-torque concept | 900 / 1100 W | Low-speed stability, gearing capacity, shaft and axial/radial loads |
| 12 | Holding-brake concept | 100 / 130 / 200 / 300 W | Holding torque, release circuit, air-loss state and validation |
| 13 | Holding-brake concept | 300 / 600 / 900 W | Holding torque, release circuit, air-loss state and validation |
| 14 | Holding-brake concept | 700 / 1600 W | Holding torque, release circuit, air-loss state and validation |
Each power value is a discussion target; values and features are not freely interchangeable. References are inquiry aids, not product models or order numbers.
Provide loaded speed, running torque, minimum starting torque, dynamic inlet pressure and available flow.
Specify stainless steel grade, housing and shaft materials, shaft form, mounting dimensions and space.
Describe temperature, media, cleaning and lubrication constraints. Assess protection, oil-free operation and certification separately.
Agree sample quantity, test conditions, tolerances, maintenance requirements and production demand.